Parsed SWM report

2045 Heartwood Court

Proposed Severance 2045 Heartwood Court · Subdivision · 2024-02-29

Consultant: Premier Engineering Solutions Engineer: Muhammad Ismail, P.Eng. P.Eng sealed Model: UNKNOWN
Credit scorecard — Mississauga bylaw

Each category awards a maximum percentage of the annual stormwater charge as credit. Evidence is extracted directly from the source PDF — no manual review.

Peak Flow
discharge reduction — not documented
0%
Water Quality
TSS removal — not documented
0%
Runoff Volume
water balance retains 20 mm on site (2% per mm, max 30% at 15 mm)
30%
Operations
BMPs + P.Eng present; sub-credit detection pending — full 20% requires explicit O&A items
20%
Net credit
Capped at 50% of annual stormwater charge
40%
Pre vs post peak discharge
Storm eventPre-dev (L/s)Post-dev (L/s)Δ
5-yr11.6716.39+40%
2-yr Construction12.14
Stormwater controls (1)
InfiltrationSoakaway Pits (2 x 20m x 2m)
Storage volume9.6 m³
Treatment volume9.6 m³
Outletoverflow

Two soakaway pits each 20m x 2m, bottom area 40m2, height 0.60m, void ratio 0.40. Infiltration rate 12.8mm/hr (design), drawdown time 46.88hrs < 48hrs. Required detention volume 8.7m3, provided 9.6m3. MOE minimum 20mm on roof area = 5.26m3 < 9.6m3 provided. Percolation test measured permeability 200mm/hr with factor of safety of 3 applied, design value 12.8mm/hr used in calculations.

Best management practices (2)
Soakaway pitsInfiltration trench
Site characteristics & report metadata
ProjectProposed Severance 2045 Heartwood Court
Project typeSubdivision
DeveloperLisa Miron Ernesto Rambaldini
PermitOZ 21-18 W7
Existing land usevacant grass land with dead trees (severed lot)
Proposed land usesingle-family residential
Site area0.37 ha
Impervious0% (pre) → 15% (post)
Water balance capture20.0 mm
Allowable release rate0.1 L/s
Extraction audit
Confidence: high Completeness: 92% Source: 53-page PDF Extractor: PARCELFLOW v1 Validation: passed
Source PDF: OZ-21-18-W7-Functional-Servicing-Report-November-2024.pdf (53 pages) Open source PDF →
Starter package
Download credit application package »
10-page PDF: pre-filled Form 2703, starter P.Eng report skeleton, submission checklist. Engineer reviews, adds site inspection + O&M plan, certifies + submits.
Download PDF »

How to read this page. Every value above was extracted from the source PDF by the PARCELFLOW report parser, which combines a layout-robust template detector with a validated extraction stage tuned to Ontario Functional Servicing and Stormwater Management reports. The four-category scorecard maps the parsed evidence onto Mississauga's credit bylaw. Numbers are estimates — engineering review still required before submitting a formal credit application to the City.